5.3 Replacement of Filter Cartridges
Filter cartridge life varies depending on usage and/or water conditions. Changes in taste, color, and flow of the water being filtered indicate that
thecartridgeshouldbereplaced.Itisrecommendedthatthefiltercartridgesbereplacedevery6months.Replacesoonerifwaterpressureat
faucet begins to drop noticeably or cartridge fails to perform satisfactorily.
WARNING:Donotusewithwaterthatismicrobiologicallyunsafeorwithwaterofunknownqualitywithoutadequatedisinfectionbeforeorafter
the system.
Procedure for replacing filter cartridge:
1. Turn off the water supply at both ends of the system.
2. Unplug the unit.
3.Depresstheredpressurereliefbuttonsonbothfilterhousings,(asmallamountofwatermaycomeoutofthereleasevalve
when the pressure is released, this is normal).
4. Using the filter housing wrench, loosen the filter housing.
5. When the filter housings, is turning freely, hold onto it with both hands while backing the housing off the threads. The housing,
filled with water and a wet filter is heavy, be cautious and ensure that you are adequately positioned to support the weight.
6.Removetheoldfilter,anddisposeinthetrash.Usedfiltersarenotconsideredhazardouswaste.
7. Empty the housing of water, and insert the new filter cartridge. Make sure the o-ring on the filter housing has not fallen off the
housing when dumping the excess water or removing the old filter.
8. Attach the filter housing onto the system.
9. Tighten the filter housing back into position lightly with your hands, (the use of the wrench should not be required). If
desired, the wrench can be used, although caution should be taken to ensure the housing is not over tightened.
10. Refill the system by opening the inlet water line just enough to fill the chamber with water.
11. Check the system for leaks.
12. If no leaks are evident, open the inlet water line completely and re-check for leaks.
13. Plug the system in and ensure that the UV lamp is operating.
14. Open the water supply line from the system.
15. Flush the system for a minimum of 5 minutes prior to use.
5.4 Seasonal Use Maintenance Requirements
Ifyoursystemisonlybeingusedseasonally,itmustbestoredproperlyforthewinter.Drainallwaterfromthesystemanddisconnectitfrom
the power source. Cap both the inlet port and the outlet port, to prevent entry of insects and small animals.
Remove the filters from the system and discard in the trash.
Before placing the system back in service, it is recommended that the household plumbing procedures described in section 3.4 be followed and
that the entire plumbing network be fully disinfected and flushed prior to using the VPS1140 system.
Installnewfiltersinthesystem,(seesection5.3).Donotre-installfiltersusedduringthepreviousseason.
Tocleananydustbuildupand/ordirtontheoutsideoftheQuartzSleeve,usealint-freeclothwithalcoholornon-abrasivescaleremover.
98
5.1 Lamp Installation and Replacement
WARNING: The lamp heats up after continuous use and can burn your skin if touched. Allow lamp to cool for at least 5 minutes before removing.
DonotoperatetheUVlampoutsideofthereactor.ThelampintheunitemitsUltravioletlightthatcancausepermanentdamagetoskinand
eyes.Neverlookatthelampwhenunitisturnedon.
HandletheUVlampbytheendsonly.Donottouchthebulbofalampwithyourfingers.Ifthesurfaceofthelampbecomesdirty,useaclean
lint-free cloth and glass cleaner to remove the dirt.
Procedure for Replacing / Installing the Ultraviolet (UV) Lamp:
1. Turn off the water supply at both ends of the system.
2. Unplug the unit.
3. DrainwaterfromtheStainlessSteelUVChamber.
4. Allow at least 5 minutes for lamp to cool.
5. Remove the connector from the end of the UV lamp.
6. RemovetheUVlampfromthequartzsleevebygentlyrotatingthelampfree.Besuretoholdthelamponlybytheceramictips.
7. InsertthenewUVlampintothequartzsleeveandattachtheconnector.
8. Refill the UV chamber by opening the water supply just enough to fill the chamber with water.
9. Check the system for leaks.
10. Ensure that the UV lamp is operating. A purple glow should be visible on the end of the gland nut.
5.2 Cleaning the Quartz Sleeve
Mineraldepositsandsedimentbuild-uponthequartzsleevewillaffectsystemperformancebydecreasingtheUVlighttransmittedthroughthe
quartzsleeveintothewatercolumn.
The proper maintenance and replacement of the Sediment and Carbon Block filters supplied with the VPS1140 system will reduce the
accumulationofmineralandsedimentresidueonthequartzsleeve.
Thequartzsleevemaybecleanedwithacommerciallyavailable,non-abrasive,scaleremoverandalintfreecloth.Cleaningofthequartzsleeve
should be done on a regular basis to ensure maximum system performance. The amount of cleaning required will be dependant upon local
water
conditions.
All traces of the cleaning solution must be fully removed from the sleeve before it is reinstalled in the system. Care should be taken to prevent
anycleaningfluidfromcomingintocontactwiththeinsidesurfaceofthequartzsleeve.
Procedure for Removing / Installing the Quartz Sleeve:
1. Turn off the water supply at both ends of the system.
2. Unplug the unit.
3. DrainwaterfromtheStainlessSteelUVChamber.
4. Allow at least 5 minutes for lamp to cool.
5. Remove the connector from the end of the UV lamp.
6. RemovetheUVlampfromthequartzsleevebygentlyrotatingthelampfree.Besuretoholdthelamponlybytheceramictips.
7. Removethequartzsleeveandcleanasnotedabove.
8. InsertquartzsleeveintotheUVchamber.
9. InsertneworoldUVlampintothequartzsleeveandattachtheconnector.
10. Refill the UV chamber by opening the water supply just enough to fill the chamber with water.
11. Check the system for leaks.
12. Ensure that the UV lamp is operating. A purple glow should be visible on the end of the gland nut.